ISO-certified Class 100 cleanroom • Secure chain of custody • 30,000+ successful recoveries
ClearQuote Data Recovery
Home›Services›RAID 10 Data Recovery
Striped mirrors · servers & NAS

RAID 10 Data Recovery you can trust

RAID 10 can survive several drive failures, unless both drives in the same mirrored pair fail. Our RAID 10 data recovery service identifies which pairs were affected, recovers the members needed, and rebuilds the stripe — priced per case after a free evaluation.

Get my free quote Read recovery guides →
Custom quote per case · pay on success
✓Free evaluation, fixed quote before work
✓ISO Class 100 cleanroom recovery
✓$0 if we can’t recover your data
✓Secure chain of custody

About raid 10 data recovery

RAID 10 combines mirroring and striping. Drives are grouped into mirrored pairs, and data is striped across those pairs. Each pair holds its own share of the data in duplicate, which gives good performance and lets the array survive the loss of one drive in each pair.

That's why which drives failed matters more than how many. Losing two drives in different pairs leaves a complete copy of everything, while losing both drives in the same pair removes a whole share of the stripe, and the array can't be read without it. Controller and backplane faults can also knock several drives offline at once, and a rebuild that runs in the wrong direction inside a pair can overwrite good data with stale data.

Recovery starts by mapping drives to pairs and pairs to stripe positions. Layouts vary: some controllers build a stripe of mirrors, others a mirror of stripes, and Linux software RAID 10 has its own layout options. Once the layout is known, we pick the best member from each pair and assemble the stripe from those images.

What we recover

  • ✓Four-drive and larger RAID 10 arrays
  • ✓Server arrays on hardware RAID controllers
  • ✓NAS volumes configured as RAID 10
  • ✓Linux software RAID 10 and nested RAID 1+0

Common failures we handle

  • •Both drives in one mirrored pair failed
  • •Multiple drives dropped after a controller or backplane fault
  • •Rebuild of a pair copied from the wrong member
  • •Array lost its configuration or shows as foreign

Before you send it in: what not to do

  • ✕Don't rebuild a pair until you know which member is current — rebuilding in the wrong direction overwrites good data.
  • ✕Don't reinitialize the array or let the controller import a foreign configuration without advice — it can rewrite the layout.
  • ✕Don't move drives between slots without labeling them — slot positions help identify pairs and stripe order.
  • ✕Don't keep running a degraded array where one pair is down to a single drive — if that drive fails, part of every large file is lost.
  • ✕Don't run file system repair on a partly failed array — it can write changes based on incomplete data.

How we recover it

1

Free evaluation and fixed quote

We test every member, gather what you know about the configuration and failure, and give you a fixed quote to approve before work begins.

2

Image all members

Failed drives are repaired in the cleanroom where needed, and every drive is imaged sector by sector.

3

Map pairs and layout

Engineers identify which drives mirror each other, the order of the pairs in the stripe, the stripe size, and the offset.

4

Choose the best member of each pair

Within each pair, we compare members to find the most current, complete copy and fill damaged areas from its partner where possible.

5

Reconstruct, extract, and verify

The array is assembled virtually from the chosen images, and files are extracted and checked before return.

Failures we handle

Multiple Drive Failure →RAID Rebuild Failure →RAID Controller Failure →

How it works

1

Free evaluation

Start online; we assess your system in our cleanroom.

2

Fixed quote

Approve a set price before any recovery work begins.

3

We recover

Certified engineers reconstruct and recover your data.

4

Pay on success

Charged only when your data is back.

Related troubleshooting guides

RAID 10 Data Recovery — common questions

How much does raid 10 data recovery cost?+
Multi-drive cases are quoted per job after a free evaluation — the price depends on the configuration, the failure, and the work involved. There's no charge for the evaluation, and you pay nothing unless we recover your data.
Two drives failed in my RAID 10. Is that survivable?+
It depends on which two. If they were in different mirrored pairs, a full copy of the data still exists. If both were in the same pair, at least one of them has to be repaired and imaged to rebuild the array.
How do you tell which drives were paired?+
By comparing the drive images. Mirrored members hold matching data, so analysis reveals the pairs and their order in the stripe even if the controller configuration is lost.
Is RAID 10 recovery different from RAID 5?+
Yes. RAID 10 has no parity to calculate. The work is identifying pairs, choosing the best copy in each, and assembling the stripe correctly, while RAID 5 relies on parity to fill in a missing member.
Is my data still recoverable?+
In most cases, yes. A device that won't boot or mount usually has a hardware fault while the data itself is intact. The key is to stop using it — don't reformat, rebuild, or keep powering it on — and let our cleanroom handle it.
How do I send in a RAID 10 system?+
Start online for a free evaluation and we'll arrange secure, insured shipping. Your system is assessed in our cleanroom, you approve a fixed quote before any work, and you only pay on a successful recovery.
How long does it take?+
Most cases are evaluated within a couple of business days of arrival, with a turnaround estimate provided alongside your quote. Emergency service is available when time is critical.

Other services

Get your RAID 10 data back.

Free evaluation, a fixed quote before any work, and $0 unless we succeed.

Confirm & get my free label